Refrigerated cooling tower

Suitable for electron microscopes, electron probes, ultra-high vacuum sputtering instruments, X-ray machines, coating machines, ion implanters, mass spectrometers, lasers, accelerators, and any other instruments that use water cooling.

Category:

Refrigerated cooling tower

Keywords:

Refrigerated cooling tower

  • Commodity name: Refrigerated cooling tower
  • Product Description
  • Technical parameters
  • Device maintenance and precautions
  • Explosion-proof certificate
    • Commodity name: Refrigerated cooling tower
    • Commodity ID: 1354058159940587520

    Suitable for electron microscopes, electron probes, ultra-high vacuum sputtering instruments, X-ray machines, coating machines, ion implanters, mass spectrometers, lasers, accelerators, and any other instruments that use water cooling.

    Main Features:

    1. Automatic circulation, automatic cooling, prevents scaling on glassware, meeting the cooling water requirements of GB/8929-88.

    2. Pre-injected high-quality water circulates within the machine, ensuring normal operation and water conservation.

    3. Suitable for electron microscopes, electron probes, ultra-high vacuum sputtering instruments, X-ray machines, coating machines, ion beam etching machines, mass spectrometers, lasers, accelerators, and other instruments requiring water cooling.

    4. The product ensures normal operation of instruments requiring constant temperature and water cooling in areas with water shortages, poor water quality, or high temperatures.

    Installation Instructions:

    1. Install the refrigeration circulating water unit horizontally in a well-ventilated indoor location. Leave sufficient space around the unit to prevent corrosion and contamination, and to facilitate operation and maintenance.

    2. Connect the water pipes according to the refrigeration circulating water installation diagram. The chilled water and cooling water should be kept separate. The water system piping should avoid changes in direction to prevent reduced water pressure. The cooling water pipes should be insulated to prevent heat loss. Ensure the entire water system is properly connected before starting the unit.

    3. The unit's pre-installed water pipe connection diameter is the standard chilled water diameter. When using remote transmission, it is recommended to use the same specification or one size smaller water pipe for connection. If the water pipe diameter is less than half the standard chilled water diameter, contact the manufacturer to determine if installation is possible; otherwise, the water pump and compressor may be damaged.

    4. This unit uses a three-phase five-wire or single-phase three-wire system. Please select the power cord according to the current value using national standard wires.

    5. This unit has undergone rigorous testing before leaving the factory. Users only need to connect the water pipes and power cord according to the wiring diagram.

    Water-cooled Installation Diagram:

    pic

    Air-cooled Installation Diagram:

    pic

  • Main Technical Parameters:

    Operating Voltage

    220V

    Compressor

    1.5 P

    Maximum Power

    1.5KW

    Water Tank Capacity

    400x400x250mm

    Insulation Class

    Class B

    Volume

    500x500x950cm

    Water Pump Head

    6m

    Weight

    35kg

    This instrument can be designed to reach 300-25000W according to customer requirements.

     

    Model

    Cooling Capacity

    Power Consumption

    Water Temperature Control Range

    Temperature Control Accuracy

    Water Outlet Pressure

    Water Outlet Flow Rate

    Water Storage Capacity

    Dimensions

    AT-IA300

    300W

    160W

    May 25

    1 degree

    0.15MPA

    2M3.H

    11L

    450×330×530

    AT-TB1000

    1000W

    550W

    May 25

    1 degree

    0.1-0.43MPA

    5-0.5M3

    25L

    490×370×940

    AT-TC1800

    1800W

    950W

    May 25

    1 degree

    0.1-0.43MPA

    5-0.5M3

    25L

    490×370×940

    AT-TD2500

    2500W

    1500W

    February 25

    1 degree

    0.1-0.43MPA

    5-0.5M3

    25L

    850×580×1100

    AT-E4500

    4500W

    2500W

    February 25

    1 degree

    0.1-0.43MPA

    5-0.5M3

    95L

    850×580×1100

    AT-F6500

    6500W

    4000W

    February 25

    1 degree

    0.1-0.43MPA

    5-0.5M3

    95L

    1250×850×1100

    AT-G9000

    9000W

    5500W

    February 25

    1 degree

    0.1-0.43MPA

    5-0.5M3

    350L

    1250×850×1400

    Water temperature and flow rate can be adjusted according to actual needs.

    Temperature control range: -0℃-2℃ can be achieved if the customer has special requirements.

    Temperature control accuracy: +0℃-1℃ can be achieved according to customer requirements.

     

  • Operation Instructions (Maintenance):

    1. The chilled water pump must not be operated without water in the tank.

    2. Avoid repeatedly switching the power switch. Turn off the main power when the equipment is not in use for extended periods.

    3. When the chilled water temperature reaches the set temperature, the compressor will automatically stop running. This is normal.

    4. When the unit is running, pay attention to the pressure gauge readings. Use the following as judgment standards: water-cooled high pressure not exceeding 20 kg/cm2, air-cooled high pressure not exceeding 24 kg/cm2, and low pressure not less than 2.0 kg/cm2. Excessively high or low readings indicate a precursor to a malfunction or improper use. Please check promptly or notify the manufacturer.

    5. The condenser and evaporator of the refrigeration circulating water unit usually require cleaning after a period of use.

    6. If the refrigeration circulating water is used for a period of time, the pump impeller may be solidified by dirt. When restarting, you must use a screwdriver to move the fan blade on the motor rear cover to prevent the impeller from jamming and burning out the motor.

    7. The ideal operating temperature for the refrigeration circulating water is 7-12℃, with an operating range of 5-35℃. If the water temperature exceeds 35℃ at startup, high-temperature protection will occur, and the compressor overload relay will trip. In severe cases, the fuse may melt and burst.

    8. Chilled water systems are highly specialized mechanical equipment and should be used and maintained by professional technicians. Non-professional personnel should not operate or repair the equipment to avoid danger.

     

  •  