I. Overview
Explosion-proof analysis cabins are used for continuous, automatic on-site measurement, analysis, and control of material components and content in production processes. They meet the special environmental conditions required by complete online analyzer systems, such as temperature, humidity, dust and explosion-proof requirements. The product has obtained explosion-proof certification from the designated national inspection agency and can be used in major oil fields, chemical, pharmaceutical, military, mining, chemical plants, power plants, coal mines, gas stations, coal washing plants, loading and unloading docks, substations, control rooms, squares, boiler rooms, cold storage, ditches, sewers, metallurgical plants, underground passages, tunnels, factory sheds, underground, cruise ships, warehouses, factories, marine use, guard posts, railways, ships, oil depots, fire trucks, towers, cranes, yachts, gas stations, billboards, maintenance rooms, roads, bridges, air conditioning boxes, etc. across the country, in hazardous locations with flammable gases.
Explosion-proof analysis cabins are a new technology that became popular internationally in the mid-1980s. It integrates the combination, assembly, and application of industrial online instruments, and was first widely used in oil refining and chemical enterprises.
The standardized and professional design of the on-site analysis room makes the on-site installation and maintenance of analyzers more convenient and provides a good operating and running environment for the instruments. It ensures the required operating environment and the accuracy of the analysis data, while also improving the service life of the analyzers, and has been increasingly used in process equipment.
Technical Description
The explosion-proof analysis cabin adopts an all-steel frame structure, with the analyzers and control units assembled inside the cabin, and the sample pretreatment and carrier gas, standard gas, and drive gas installed outside the cabin. The sampling probe and the primary pressure reduction station are installed near the process pipeline. The cabin is equipped with explosion-proof air conditioning, explosion-proof electric heaters or steam heating equipment (optional), which can adjust the indoor temperature. The power distribution system is a pipeline system, equipped with explosion-proof distribution boxes, explosion-proof junction boxes, etc.
The lighting system uses explosion-proof fluorescent lamps and explosion-proof emergency fluorescent lamps. The cabin is also equipped with ventilation, air exchange, and filtration devices, which can be timed for ventilation and air exchange to keep the indoor air fresh. The cabin is also equipped with an alarm interlocking panel (including gas sensors and controllers) and audible and visual alarm lights. When flammable/toxic gas leaks, the audible and visual alarm lights will sound an alarm to protect personal safety. The explosion-proof type of the analysis cabin is divided into two types: flameproof (natural ventilation) and positive pressure type (positive pressure ventilation).
It is used in the production of oil refining, chemical, metallurgical, pharmaceutical, and light industries to provide a safe on-site installation space and protection for various process gas online analyzers and various online water quality analyzers.
-
II. Main Technical Parameters
Rated Voltage: AC220/380V Explosion-proof air conditioner power: 1.5 HP
Ventilation method: Continuous +Gap Explosion-proof electric heater power: 2KW
Gas source pressure: 0.3~1.0MPa Explosion-proof fluorescent lamp: 2x40W
Gas consumption: 2.0~25m3/h Explosion-proof emergency light: 1x40W
Protection level :IP65 Gas source interface: G1/2’
III. Product Features
Includes explosion-proof distribution box, explosion-proof junction box, explosion-proof fluorescent lamp, explosion-proof emergency light, etc.
Explosion-proof air conditioner, explosion-proof electric heater or steam heating equipment can be installed as needed.
Workbenches, analyzers, etc. can be installed as needed.
The analysis cabin has the advantages of shockproof, anti-static, spark-proof, dust-proof, and anti-interference, providing a good operating environment for instruments.
The external dimensions of the analysis cabin are determined according to user needs.
Explosion-proof analysis cabin with buffer room
-
IV. Safety Measures
1. A small, continuous flow of gas is introduced into the cabin, along with intermittent gas injections, to ensure fresh and safe air within the cabin.
2. A combustible gas detector is installed inside the cabin. If combustible gas is detected, the detector will activate, the alarm light will illuminate, the explosion-proof bell will sound, and the explosion-proof solenoid valve and explosion-proof exhaust fan will automatically power on. At this time, a large amount of fresh air will be introduced into the cabin, expelling air containing explosive gases to ensure cabin safety.
3. The cabin has good internal and external grounding.